maxwell_pro
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
maxwell_pro [2017/04/06 23:12] – dwallace | maxwell_pro [2017/04/11 10:34] (current) – dwallace | ||
---|---|---|---|
Line 3: | Line 3: | ||
**Author:** Dylan Wallace Email: < | **Author:** Dylan Wallace Email: < | ||
\\ | \\ | ||
- | **Date:** Last modified on 04/04/17 | + | **Date:** Last modified on 04/06/17 |
\\ | \\ | ||
**Keywords: | **Keywords: | ||
Line 27: | Line 27: | ||
\\ | \\ | ||
The rest of this tutorial is presented as follows: | The rest of this tutorial is presented as follows: | ||
- | * [[maxwell_pro# | + | * [[maxwell_pro# |
- | * [[maxwell_pro# | + | * [[maxwell_pro# |
* Final Words | * Final Words | ||
Line 55: | Line 55: | ||
pass: maxwell | pass: maxwell | ||
| | ||
- | Once logged in, the Maxwell Pro will auto-obtain its IP address via DHCP. In my case this IP address was **192.168.1.121**, | + | Once logged in, the Maxwell Pro will auto-obtain its IP address via DHCP. In my case this IP address was **192.168.1.121**, |
ifconfig | ifconfig | ||
Line 84: | Line 84: | ||
===== DRC Degraded Communications ===== | ===== DRC Degraded Communications ===== | ||
+ | |||
+ | In this section, we will learn how to setup and use the DARPA Robotics Challenge (DRC) Degraded Communications Emulator (DCE) software. First, you will need to download and install Python 2.7. Instructions for this can be found [[https:// | ||
+ | |||
+ | Once you have properly setup Python 2.7, download the DRC-DCE Software, which I have provided as a {{dylanw: | ||
+ | |||
+ | Once you have downloaded these to your preferred directory, navigate into that directory and execute the following command: | ||
+ | |||
+ | | ||
+ | |||
+ | Note that the Maxwell Pro IP is the one that we recorded in the beginning of this tutorial. Once you execute this command, your screen should look similar to the following: | ||
+ | |||
+ | {{ dylanw: | ||
+ | \\ \\ \\ | ||
+ | When we press " | ||
+ | \\ \\ \\ | ||
+ | {{ dylanw: | ||
+ | \\ \\ \\ | ||
+ | Now, we can interact with the software. We will press " | ||
+ | \\ \\ \\ | ||
+ | {{ dylanw: | ||
+ | \\ \\ \\ | ||
+ | This will setup the 300 Mbit/s UDP connection from the robot PC to the operator PC, and the 9600 bit/s TCP connection between the operator PC and the robot PC. However, the UDP connection will not experience " | ||
+ | \\ \\ \\ | ||
+ | {{ dylanw: | ||
+ | \\ \\ \\ | ||
+ | When we are done using thsi software to test our connections, | ||
+ | \\ \\ \\ | ||
+ | {{ dylanw: | ||
+ | \\ \\ \\ | ||
+ | From there, we can restart if needed, by pressing the " | ||
+ | |||
+ | Now you know how to operate the basics of the Maxwell Pro Degraded Communications Emulator. | ||
===== Final Words ===== | ===== Final Words ===== | ||
- | This tutorial' | + | This tutorial' |
- | \\ | + | \\ |
- | \\ | + | Speculating future work derived from this tutorial, includes |
- | Speculating future work derived from this tutorial, includes | + | \\ |
- | \\ | + | |
- | \\ | + | |
For questions, clarifications, | For questions, clarifications, |
maxwell_pro.1491545545.txt.gz · Last modified: 2017/04/06 23:12 by dwallace